This trouble-shooting is carried out by qualified technicians only.
Problem
Possible cause
Possible solution
Motor does not
work
- Mains supply is not connected
- Incorrect electrical connection
or power source
- Circuit breaker(12A) if shut-off
Check mains power, and reset
(push) circuit breaker if necessary
Unusual noise
increased
- Check cooling fan
- Motor side is noisy
- Leak air from tubing, check
valve or dryer
- If fan is broken or not fitted correctly,
change or fit correctly
- Call to authorized dealer
- Call to authorized dealer
Excessive
vibration
- Inside part of compressor head
damaged
Call to authorized dealer
Unit is very hot
- Wrong wiring
- Low voltage
- Intake filter is clogged or dirty
- Installation place is too hot
- Check wiring
- Supply proper voltage
- Clean primary filter
- Cool ventilation is necessary
Air supply is
too low
- Leak air
- Disconnect main power supply.
Drain storage tank
- Close tank outlet valve and turn on
the power
- Check which part is leak and call to
authorized dealer
Compressor
pressure is not
reach 8bar
- Leak air
- Pressure switch need to
adjusted
-Same remedy above
-Call to authorized dealer to adjusted
SECTION 6. TROUBLE SHOOTING CHART