Solar Pump Inverter Chapter 4 Function Parameters
33
Code Name Description
Factory
Default
Attri
bute
F07.09
Rotating speed
display coefficient
0.1~999.9%
Mechanical speed=120*display
frequency×F07.09/Number of motor
pole pairs
100.0%
F07.10
Linear speed display
coefficient
0.1~999.9%
Linear speed=Mechanical
speed×F07.10
1.0%
F07.11
Rectification bridge
temperature
0~100.0
F07.12
Converting module
temperature
0~100.0
F07.13
Software version
1.00~655.35
F07.14
Accumulative running
time
0~65535h
F07.18
Inverter Rate Power
0.4~3000.0kW
F07.19 Inverter Rate Voltage 50~1200V
F07.20
Inverter Rate Current
0.1~6000.0A
F07.27 Now Fault Type 0Not fault
1Over-current when acceleration
OC1
2Over-current when deceleration
OC2
3Over-current when constant
speed runningOC3
4Over-voltage when acceleration
OV1
5Over-voltage when deceleration
OV2
6Over-voltage when constant
speed runningOV3
7DC bus Under-voltageUV
8IGBT Ph-U faultOUT1
9IGBT Ph-V faultOUT2
10IGBT Ph-W faultOUT3
11Motor overloadOL1
12Inverter overloadOL2
13overload alarmOL3
14IGBT overheatOH1
15Rectify overheatOH2
16Input phase failureSFI
17 Output phase failureSFO
18Brake unit faultbCE
19Ground short-circuit fault (ETH)
20Under load fault (LL)
21Communication faultE.485
22External faultEF
23EEPROM faultEEE
24Trial time reachedEND
F07.28
Latest Fault Type
F07.29
The Second Fault
Type
F07.30
The Third Fault Type
F07.31
The Fourth Fault
Type
F07.32
The Fifth Fault Type