Solar Pump Inverter Chapter 4 Function Parameters
34
Code Name Description
Factory
Default
Attri
bute
25Current detection fault (ItE)
32Short to ground fault 1(ETH1)
33Short to ground fault 2(ETH2)
36Low-load fault(LL) Warning:
A-LSLack sunlight
A-tFwater full
A-LLlack water source
A-LL1
water source drain
F08 Group: Auxiliary function
F08.00 ACC time 2 0.03600.0s
Depend on
mode
F08.01
DEC time 2
0.03600.0s
Depend on
mode
F08.02 ACC time 3 0.03600.0s
Depend on
mode
F08.03 DEC time 3 0.03600.0s
Depend on
mode
F08.04 ACC time 4 0.03600.0s
Depend on
mode
F08.05 DEC time 4 0.03600.0s
Depend on
mode
F08.06
Jogging frequency
0.00
F00.03 (Max. frequency)
5.00Hz
F08.07
Jogging running ACC
time
0.03600.0s
Depend on
mode
F08.08
Jogging running DEC
time
0.03600.0s
Depend on
mode
F08.28
Fault Auto Reset
Times
0~10 5
F08.29
Reset Interval
0.1~3600.0s
2.0s
F08.32
FDT1 level detection
value
0.00F00.03 (Max. frequency) 50.00Hz
F08.33
FDT1 lag detection
-100.0
100.0% (FDT1 level)
5.0%
F08.34
FDT2 level detection
value
0.00F00.03 (Max. frequency) 50.00Hz
F08.35
FDT2 lag detection
-100.0
100.0% (FDT2 level)
5.0%
F08.36
Frequency arrival
detective value
0.00F00.03 (Max. frequency) 0.00Hz
F08.37
Energy consumption
brake enable
0: brake disable
1: brake enable
0
F08.38
Braking threshold
voltage
200.0~2000.0V(220V
voltage:380.0V)
Depend on
voltage
200.0~2000.0V(380V
voltage:700.0V)
200.0~2000.0V(660V
voltage:1120.0V)
F08.39
Running mode of
cooling fan
0: normal running mode
1: keep running after power on
0