Solar Pump Inverter Chapter 4 Function Parameters
34
Code Name Description
Factory
Attri
25:Current detection fault (ItE)
32:Short to ground fault 1(ETH1)
33:Short to ground fault 2(ETH2)
36:Low-load fault(LL) Warning:
A-LS:Lack sunlight
A-tF:water full
A-LL:lack water source
:
F08 Group: Auxiliary function
F08.00 ACC time 2 0.0~3600.0s
Depend on
○
F08.01
DEC time 2
0.0~3600.0s
Depend on
mode
○
F08.02 ACC time 3 0.0~3600.0s
Depend on
○
F08.03 DEC time 3 0.0~3600.0s
Depend on
mode
○
F08.04 ACC time 4 0.0~3600.0s
Depend on
○
F08.05 DEC time 4 0.0~3600.0s
Depend on
mode
○
~
F08.07
Jogging running ACC
time
0.0~3600.0s
Depend on
mode
○
F08.08
Jogging running DEC
0.0~3600.0s
Depend on
○
F08.28
Fault Auto Reset
Times
0~10 5 ○
F08.32
FDT1 level detection
value
0.00~F00.03 (Max. frequency) 50.00Hz ○
~
F08.34
FDT2 level detection
value
0.00~F00.03 (Max. frequency) 50.00Hz ○
~
F08.36
Frequency arrival
detective value
0.00~F00.03 (Max. frequency) 0.00Hz ○
F08.37
Energy consumption
0: brake disable
0 ○
F08.38
Braking threshold
voltage
200.0~2000.0V(220V
voltage:380.0V)
Depend on
voltage
○
200.0~2000.0V(380V
voltage:700.0V)
200.0~2000.0V(660V
voltage:1120.0V)
F08.39
Running mode of
0: normal running mode
1: keep running after power on
0 ○