EasyManua.ls Logo

dolycon CT112 Series - Page 42

dolycon CT112 Series
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Solar Pump Inverter Chapter 4 Function Parameters
38
Code Name Description
Factory
Default
Attri
bute
F15.10 PI Amplitude 0.0~6553.5Vdc
25.0V
/30.0V
/60.0V
Depend on
mode
F15.11 Dry Pump Function
0: Disabled
1: Enabled
1
F15.12
Dry-Water Threshold
0.0~100.0%
0.0%
F15.13
Delay Time of
Dry-Water
0~3600.0s 60.0s
F15.14
Wake-up Delay Time
of Dry-Water
0~3600.0s 600.0s
F15.15 POWER SELECT
0: motor
1: UI
0
F15.16
Over-heat reduced
frequency
0.00~10.00Hz/ 3.00Hz/
F15.17
Delay Time of
Full-Water
0.0~3600.0s 60.0s
F15.18
Reset Delay of
Full-Water
0.0~3600.0s 120.0s
F15.19
Frequency of Weak
Light
0~50.00Hz
5.00Hz
(CT112)
15.00Hz
(CT112A)
F15.20
Delay Time of Weak
Light
0.0~3600.0s 600.0s
F15.21
Reset Delay of Weak
Light
0.0~3600.0s 300.0s
F15.22
Reference Voltage of
Given Display
0.0~2000.0V 0V
F15.23
Min. Voltage of
MPPT
0.0~6553.5Vdc 50.0V
F15.24
Max. Voltage of
MPPT
0.0~6553.5Vdc 780.0V
F15.25
KP3
(CT112A special)
0.00~100.00 40.00
F15.26
KI3 (CT112A special)
0.00~100.00
5.00
F15.27
Boost Voltage set
(CT112A special)
0.0~6553.5Vdc 330.0V
F15.28
KP4
(CT112A special)
0.00~100.00 20.00
F15.29
KI4
(CT112A special)
0.00~100.00 5.00
F17 Group: Status view function
F17.00 Set frequency 0.00Hz~F00.03
0.00Hz
F17.01
Output frequency
0.00Hz~F00.03
0.00Hz
F17.02
Slope given
frequency
0.00Hz~F00.03 0.00Hz

Related product manuals