CLIMATE CONTROL
AIR CONDITIONERS
Form No. 3317817.000 1/21 | ©2021 Dometic Corporation
WARNING
Cancer and Reproductive Harm
www.P65Warnings.ca.gov
Brisk Air (457915, 459516), Brisk II (B57915, B59516),
High Performance (540315, 540316), Blizzard NXT (H540315, H540316),
Penguin (640312, 640315, 640316), Penguin II (640312C, 640315C, 640316C),
FreshJet (FJX3473, FJX3573)
EN
Value Air Distribution Box,
Mechanical
Installation and Operation Manual . ........2

Questions and Answers:

Dometic 640315C Specifications

General IconGeneral
Model640315C
TypeRooftop Air Conditioner
Cooling Capacity13, 500 BTU/h
Voltage115V
Power SupplyAC
EER9.0
Operating Current12.5 A
Air Flow320 CFM
Weight77 lbs (35 kg)

Summary

Explanation of Symbols and Safety Instructions

Recognize Safety Information

Explains the safety alert symbol and its meaning to prevent potential injury.

Understand Signal Words

Defines signal words like DANGER, WARNING, CAUTION, and NOTICE to indicate hazard severity.

Supplemental Directives

Provides important directives to reduce accident and injury risks during product installation, operation, or service.

General Safety Messages

Lists critical safety warnings concerning electrical shock, fire, and explosion hazards.

Intended Use

General Information

Tools and Materials

Lists the recommended tools and materials required for the installation process.

Model Identification

Explains how to locate model and serial number identification labels on the unit.

ADB Components

Identifies and illustrates the main components of the Air Distribution Box (ADB).

Rooftop Component Dimensions by Model

Provides external dimensions and clearance measurements for various rooftop AC models.

Freshjet Rooftop Component Dimensions

Details dimensions and clearances for the Freshjet model.

Brisk Air Rooftop Component Dimensions

Details dimensions and clearances for the Brisk Air model.

Brisk II Rooftop Component Dimensions

Details dimensions and clearances for the Brisk II model.

Blizzard NXT Rooftop Component Dimensions

Details dimensions and clearances for the Blizzard NXT model.

High Performance Rooftop Component Dimensions

Details dimensions and clearances for the High Performance model.

Penguin Rooftop Component Dimensions

Details dimensions and clearances for the Penguin model.

Penguin II Rooftop Component Dimensions

Details dimensions and clearances for the Penguin II model.

ADB Component Dimensions

Provides the internal dimensions of the Air Distribution Box (ADB) component.

Placement Requirements

Specifies the requirements for positioning the rooftop component on the RV, including structural support.

Tilt Requirements

Outlines the acceptable tilt requirements for rooftop component placement on the RV roof.

Specifications

Wiring Diagrams

Pre-Installation

Determining Your Cooling Needs

Guides the user on factors to consider when determining appropriate cooling requirements for the RV.

Preparing the RV Roof Opening

Details the process of preparing the RV roof opening, ensuring structural integrity and proper fit.

Using an Existing Roof Vent Opening

Provides instructions for preparing the roof opening when an existing vent is present.

Making a New Roof Opening

Provides instructions for creating a new roof opening if no existing vent is available.

Routing the Wiring

Describes the correct procedure for routing the 115 VAC power supply wiring for the rooftop component.

Positioning the Rooftop Component

Provides instructions on how to correctly move and place the rooftop unit over the prepared opening.

Installation

Installing the Foam Dividers

Explains how to install foam dividers to fill gaps based on specific roof thicknesses.

Roof Thickness 1.25 to 5.5 in. Foam Dividers

Table guiding foam divider selection for roof thicknesses from 1.25 to 5.5 inches.

Roof Thickness 6.0 - 7.5 in. Foam Dividers

Table guiding foam divider selection for roof thicknesses from 6.0 to 7.5 inches.

Securing the Unit

Details the process of securely fastening the rooftop component to the RV roof using mounting bolts.

Wiring the Unit to the Power Supply

Explains how to connect the unit's internal wiring to the main power supply.

Connecting the Power Supply

Details connecting the 115 VAC power supply wire and the 6-pin unit electrical cord.

Finalizing the Installation

Covers the final steps to complete the ADB installation, including filter and cover placement, and power-up.

Operation

Understanding the Controls

Explains the function and operation of the temperature and fan control knobs.

Understanding the Settings

Details the available settings for cooling and fan-only operation modes.

Cooling Operation

How to use the cooling settings for effective temperature control and dehumidification.

Fan-Only Operation

How to use the fan-only settings for air circulation and ventilation without cooling.

Cooling Fan Operation

How to use the fan settings in conjunction with cooling for optimal air distribution.

Maintenance

Cleaning the Air Filter

Instructions for periodic cleaning of the air filter to maintain unit performance.

Cleaning the ADB Housing

Guidance on cleaning the Air Distribution Box housing and control panel using mild detergent.

Troubleshooting

Disposal

Limited Two-Year Warranty