CF50SG Operation
15
In “HIGH” mode, the battery monitor responds faster than at the levels “LOW” and
“MED” (see the following table).
Selecting the battery monitor mode
➤ Switch on the cooler.
➤ Press the “SET” button (fig. 2 4, page 9) three times.
➤ Use the “UP +” (fig. 2 6, page 9) and “DOWN –” (fig. 2 7, page 9) buttons to
select the battery monitor mode.
✓ Display will be as follows:
Lo (LOW), Πed (MED) or HI (HIGH)
✓ The selected mode then appears in the display for a few seconds. The display
flashes several times before it returns to the current temperature.
I
Battery monitor mode LOW MED HIGH
Switch-off voltage at 12 V
10.1 V 11.4 V 11.8 V
Restart voltage at 12 V
11.1 V 12.2 V 12.6 V
Switch-off voltage at 24 V
21.5 V 24.1 V 24.6 V
Restart voltage at 24 V
23.0 V 25.3 V 26.2 V
NOTE
When the cooler is supplied by the starter battery, select the battery
monitor mode “HIGH”. If the cooler is connected to a supply battery,
the battery monitor mode “LOW” will suffice.
If you wish to operate the cooler from the AC power supply, set the
battery monitor to the “LOW” position.
CF50SG-O-AUS.book Seite 15 Dienstag, 19. Mai 2020 1:06 13