6.5 Connecting the gas
FIRE OR EXPLOSION HAZARD. Failure to obey the following warnings could result in property
damage, serious injury, or death:
Install gas connections in compliance with the applicable supplemental directives listed in this manual. Refer
to"1.3 Supplemental directives" on page 3.
Never use an open flame to check for gas leaks. Use a commercial leak detection solution to check all
connections, as specified in these instructions.
Should the gas supply fail to shut off or if overheating occurs, shut off the gas valve to the refrigerator before
shutting off the electrical supply.
Do not put sealing compound on flair fittings.
Never use a wire or pin to clear obstructions from burner jet (damage will occur).
Do not attempt to adjust burner jet.
I
Read before proceeding:
Connection to the gas supply line is accomplished at the manual gas valve. The manual gas valve is furnished
with a 3/8" SAE (UNF 5/8" -18) male flare connection.
The gas supply system must incorporate a pressure regulator to maintain a supply pressure of not more than
11" water column.
When testing the gas supply system at test pressures:
greater than 1/2 psi, the refrigerator and its individual shutoff valve must be disconnected from the gas
supply piping system.
1/2 psi, or less, the refrigerator must be isolated from the gas supply piping system by closing the
individual manual shutoff valve.
If local codes allow for the use of a flexible gas appliance connector, do not use a connector that has
previously serviced another gas appliance.
If detailed instructions on the installation and connection to the gas supply are required, contact the nearest
dealer or distributor.
Always use two wrenches to hold the valve and flair nut when loosening and tightening gas connections.
Route all connections to avoid contact with the boiler casing, burner cover, or any other refrigerator
components.
Perform an air pressure test on the piping system.
Examine all completed connections for leaks using a commercially available soap solution made for the
detection of leaks.