Your microwave oven is shipped with the vent motor assembled for wall venting. If you want roof-venting or
room-vented (recirculating) installation, you must change the fan, as detailed below.
ELECTRICAL SHOCK HAZARD!
UNPLUG UNIT BEFORE WORKING ON IT.
DO NOT PULL OR STRETCH THE BLOWER WIRING! Pulling and stretching the blower wiring could
result in electrical shock.
ROOM-VENTED (Recirculating)
INSTALLATION:
1. Remove ventgrille by removing two screws on the
ventgrille
2. Turn two mounting rods anti-clockwise with flat
blade screwdriver and take off the mounting plate
from the unit. See figure 11.
3. The vent motor in your microwave oven is installed
for room vented installation at shipping.
ROOF-VENTED INSTALLATION:
1. Remove ventgrille by removing two screws on the
ventgrille
2. Turn two mounting rods anti-clockwise with flat
blade screwdriver and take off the mounting plate
from the unit. See figure 11.
3. Detach mount-all from out case by removing two
mount-all mounting screws and one motor
mounting screw. See figure 12.
4. Keep the motor wire being connected , lift up,
rotate and reattach the motor so that the exhaust
ports face the upper of the cabinet. See figure 13.
5. Use side cutters or tin snips to cut and remove
knockouts from mount-all. Be careful not to distort
the plate. See figure 14.
6. Reattach the mount-all on the cabinet with three
screws.
STEP 3:
PREPARE THE VENT MOTOR
mount-all
mounting screws
mount-all
motor
mounting screw
Vent motor
Figure 12
Figure 13
back plate
exhaust ports
motor wire
Remove
mounting
plate.
Figure 11
Vent Grille
Controller
Mounting
Plate
Mounting
Rod
Door
Out Case
Mount-all
Flat blade
screw driver
(2-screw positions
are optional.)
W A R N I N G