Troubleshooting FW 3000
EN
10
The recirculation air is drawn in through a grille or through other openings with a total cross-section of at least
300 cm². The recirculation air opening (2) must be created near the machine. If this is not possible, make sure that
the air flow must not be obstructed by anything; if necessary, create an air duct between the opening and the
machine.
I
The recirculation air must be taken from inside the passenger compartment; if taken from the outside then the effi-
ciency of the under-bench air conditioner will be reduced.
8 Troubleshooting
NOTE
To avoid condensation on the pipes insulate the pipes with insulation material (not
included in the scope of delivery).
Problem Cause Remedy
No cooling
capacity
The under-bench air conditioner is not set to
cooling.
Set the under-bench air conditioner to
cooling.
The ambient temperature is above 52 °C. The under-bench air conditioner is only
designed for ambient temperatures of up to
52 °C.
The temperature set is higher that the room
temperature.
Select a lower temperature.
The ambient temperature is below 16 °C. The under-bench air conditioner is only
designed for ambient temperatures above
16 °C.
The thermal protection is defective. Contact an authorized workshop.
The compressor is damaged.
The refrigerating agent filling is insufficient.
The heat exchange coils are polluted.
The external blower is defective.