Note on installation location
To install the machine it is necessary to create openings in the floor. These open-
ings must be accessible and must not be covered by any parts of the vehicle.
Before installing the under-bench air conditioner, check whether any vehicle
components could be damaged by the installation of the under-bench air
conditioner (such as lamps, cupboards, doors).
Make sure no combustible objects are stored or installed near the air outlet. A
distance of at least 50 cm should be kept.
The inclination of the installation surface may not exceed 10°.
For safety reasons, note the location of existing wiring harnesses, wires and other
components within the installation area, in particular those which are not visible,
when installing the under-bench air conditioner (when drilling or screwing etc.).
To obtain the optimal air-conditioning in the vehicle, install the under-bench air
conditioner in a central position, in a compartment or a similar housing.
Choose a place that is easily accessible for servicing as well as disassembling and
installing.
Place the assembly template into the chosen compartment and check the space
available for the openings in the floor.
To minimize the transmission of noise and vibration during operation, the under-
bench air conditioner should have a all around minimum clearance of 30 mm to
walls and furniture.
The under-bench air conditioner must be installed on the floor.
Keep a distance of 200 mm between the front of the under-bench air conditioner
and the walls of the compartment to facilitate filter replacement.
Installing the under-bench air conditioner into an external compartment (e.g.
false bottoms), the air to be treated must be drawn in from the vehicle’s
passenger compartment.
Suctioning of outside air can significantly reduce the power of the system.