HiPro Troubleshooting
17
9 Troubleshooting
Fault Possible cause Solution
Not cooling Power plug not plugged in Insert power plug into
socket
No voltage at socket Check circuit breaker
Electronics or sensors defective Contact service
agent.
Service agent: Install
new electronics or
sensor
For versions with absorber
cooling: Heating cartridge defective
Contact service
agent.
Service agent: Install
new heating cartridge
Auto-defrost active (see chapter
“Defrosting” on page 15)
No action required
Minibar recently switched on Check cooling again
after 5 to 6 hours
Cooling unit defective Contact service
agent.
Service agent:
Replace minibar
Minibar is in silent mode. No action required
Not cooling, indicator
LED continuously flash-
ing
Cooling unit blocked Contact service agent
Cooling unit not water-tight
Heating element defective
Error during self-test