This refrigerator is equipped with overheating
protection. An authorised service technician can
check whether this has been triggered or not.
In the event of a fault developing, contact your
nearest Service Centre-see local telephone
directory.
13. Putting into operation
Technical data:
Model RH 131 RH 141
Type MF20-60 MF20-60
Gross volume 31 litre 41 litre
Mains operation 220V (AC) 220V (AC)
Input 90W 90W
Energy
consumption
0.9 kWh/24h 0,98 kWh/24h
Climate class N N
Refrigerant 159g H
2
O+86g
NH
3
159g H
2
O+86g
NH
3
13.1. Connecting to electrical mains
The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected to a mains socket earthed in accordance
with regulations. Any electrical work required to install this appliance should be carried out by a
qualified electrician or competent person.
The manufacturer declines any liability should these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity supply voltage is the same as that indicated on the
appliance rating plate.
Only for UK:
The appliance is supplied with a 3 amp plug fitted. In the event of having to change the fuse in the
plug supplied, a 3 amp ASTA approved (BS 1362) fuse must be used. Should the plug need to be
replaced for any reason, the wires in the mains lead are coloured in accordance with the following
code:
Green and Yellow: Earth
Blue: Neutral
Brown: Live
The wire coloured
green
and yellow
must
be
connected to the terminal marked with the letter .E. or by the earth symbol
or coloured green and yellow.
The wire coloured blue must be connected to the terminal .N. or coloured black.