How to fix insufficient or nonexistent flow in my Dometic P062?
- AAlan HallAug 11, 2025
If the Dometic Water Pump's flow is insufficient or nonexistent, it could be due to several reasons. First, check for air leaks in the suction piping and tighten the seals. Ensure the pump head is filled with fluid before starting. Verify the system head meets application requirements, as a larger pump may be needed. Make sure the suction and discharge valves are open. Check the fluid mixture concentrations if the viscosity or specific gravity is too high. Ensure proper inlet pressure, positioning the pump below water level or in a fully pressurized loop if the suction lift is too high. Also, inspect the inlet strainer and pump lines for clogs. Finally, confirm the motor wiring matches the pump's wiring diagram.