EasyManua.ls Logo

Dometic P062 - General Information; Specifications; Maximum Surface Temperature; Minimum Flow Rate

Dometic P062
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
EN
Magnetic-Drive Centrifugal Pump General Information
Mounting location (directly to floor plates, rails with
vibration isolators to reduce noise, platforms, etc.)
Suitable mounting hardware for desired installation
or use
Suitable piping for desired installation or use (for
example: Schedule 80 PVC, CPVC, copper piping,
stainless steel, flexible hose, etc.)
Single-phase or three-phase electrical wiring
This manual provides all necessary information for
proper installation and operation of the pump. Poor
installation and improper operating procedures will
result in unsatisfactory performance and possible failure.
The manufacturer accepts no liability for damage in the
following cases:
Faulty assembly or connection
Damage to the product resulting from mechanical
influences and excess voltage
Alterations to the product without express permission
from the manufacturer
Use for purposes other than those described in this
manual
Dometic Corporation reserves the right to modify
appearances and specifications without notice.
3 General Information
I
The images used in this document are for reference
purposes only. Components and component
locations may vary according to specific product
models.
Recommended Tools and Materials
Wire Strippers and Crimper Phillips-head Screwdriver
Weatherproof Wire Nuts Socket Wrenches
5/16 in. (8 mm)
3/8 in. (9 mm)
1/2 in. (13 mm)
5/8 in. (16 mm)
3/4 in. (19 mm)
Other hardware sufficient for
secure mounting at desired
location
Additional Tools and Materials for Optional Steps
Drill Press Waterproof Pipe Sealant or
Tape
7/16 in. Drill Bit Drain Plug or Valve
1/4 in. NPT Tap Waterproof Electrical Tape
Arbor Press Plastic or Wooden Sha
4 Specifications
The major pump parts are glass-filled polypropylene for
superior corrosion resistance.
I
For best performance, maintain operation of
this pump within the following specifications.
Additional specifications for each pump are
available online at www.dometic.com.
4.1 Maximum Surface Temperature
The maximim allowable surface temperature of the
pump is 180 °F (82 °C).
4.2 Minimum Flow Rate
See the table below for the minimum flow rates by
model.
Model 3450 rpm 2900 rpm
P030 0.3 gpm (.9 lpm) 0.3 gpm (.9 lpm)
P045
P062
P075
P100
0.5 gpm (1.9 lpm) 0.5 gpm (1.9 lpm)
P137 4 gpm (15 lpm) 3.4 gpm (12.9 lpm)
P150 5 gpm (18.9 lpm) 4.2 gpm (15.9 lpm)
P200 10 gpm (37.8 lpm) 10 gpm (37.8 lpm)

Related product manuals