PLB40 Using the appliance
11
➤ If charging the battery pack with a solar panel, observe the following
requirements:
– Use without a solar controller:
Ensure that the solar panel outputs between 8 – 25 V DC and a maximum
charging current of 10 A.
– Use with a solar controller:
Ensure the solar charger does not need a counter voltage from the battery
side to start charging. Ensure that the maximum charging current is 10 A
(check with the solar panel manufacturer).
6.4 Checking the charge level
➤ Press the power button (fig. 2 1, page 5).
✔ The display shows the battery state of charge as a percentage.
✔ The symbol flashes when the battery capacity is below 20 %.
6.5 Connecting consumer devices
fig. 2, page 7
➤ Open the cap for the desired device:
–USB devices (3)
–2-pin 12VDC socket outlet (4)
–12VDC socket (5)
➤ Insert your device’s plug into the corresponding socket.
✔ The symbol and the related output symbol light up.
6.6 Replacing fuses
➤ Ensure that the battery pack is not connected to an AC/DC or a DC/DC charger.
➤ Disconnect all loads.
➤ Press the power button for at least 3 s to switch the battery pack off.
➤ Undo the fuse holder.
➤ Replace the fuse with a 20 A 3 AG glass-slow acting fuse.