RCD10.5 Troubleshooting
25
RCD10.5ES, RCD10.5XES
In the event of a fault, the warning LED (
) in the display flashes.
All faults of the WARNING (W) type are reset automatically once the fault has been
rectified.
All faults of the ERROR (E) type must be reset manually:
➤ Press for 2 seconds.
✔ A beep sounds.
✔ The error has been reset.
Code Audio alarm Fault Solution
W02 No Defective temperature sen-
sor in the refrigerator com-
partment
➤ Contact an authorized cus-
tomer service point.
E03 Yes Communication error ➤ Press the on/off button for at
least 2 seconds.
W04 No CI bus fault Resets automatically
W10 Yes Door open for more than
2minutes
➤ Close the door.
W11 Yes DC voltage <7.5 V Resets automatically
W19 Yes DC voltage <10.9 V Resets automatically
E32 Yes Outer fan overcurrent ➤ Press the on/off button for at
least 2 seconds.
E33 Yes Compressor does not start ➤ Press the on/off button for at
least 2 seconds.
E34 Yes Compressor overload ➤ Press the on/off button for at
least 2 seconds.
E35 Yes Thermal cut out compressor
controller unit
➤ Press the on/off button for at
least 2 seconds.
Number of
flashes
Audio alarm Fault type Fault Solution
Continuous No W Defective temperature sen-
sor in the refrigerator com-
partment
➤ Contact an author-
ized customer ser-
vice point.
1 Yes W DC voltage <10.9 V Resets automatically