EasyManuals Logo

Dometic RM2190 Series User Manual

Dometic RM2190 Series
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
REFER
SYMPTOM
CAUSE
SECTION
STEP
8.
Insufficient cooling on AC
-
cools
AC Volts
2
properly on other mode(s). (RM2201)
Heating Element
3
Thermostat
5.5
9.
Insufficient cooling on gas.
LP Gas Pressure
6
Cools properly on other mode(s).
Thermostat
7.3
Filter
7.2
Orifice
7.10
Burner
7.6
Flue Baffle
7.7
Flue Tube
7.9
10.
Won’t stay lit on gas.
LP Gas
6
Safety Valve
7.4
Thermocouple
7.5
Flue Baffle
7.7
Crossover Tube
7.8
Orifice
7.10
Burner
7.6
11.
No DC operation
-
cools properly on
DC Volts
4
other mode(s).
Heating Element
5.4
Switch
5.1
A or B
Wiring
8.2
12.
Insufficient cooling on DC- cools properly
DC Volts
4
on other mode(s).
Heating Element
5.4
2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic RM2190 Series and is the answer not in the manual?

Dometic RM2190 Series Specifications

General IconGeneral
BrandDometic
ModelRM2190 Series
CategoryRefrigerator
LanguageEnglish

Related product manuals