15
TROUBLESHOOTING
ERROR CODES
For information about error codes, refer to the following table. The codes are displayed ashing (alternating between tem-
perature and message). If an error code is displayed, contact a Dometic dealer or Service Center.
After having solved the problem, turn refrigerator OFF and then back ON. The refrigerator will return to normal operation.
ERROR CODES INFORMATION
E0 No communication between display and power module.
E1
Disconnected LP gas valve or hardware fault in the LP gas operation system. The refrigerator
may still be operational on 120 VAC.
E2
A failure of the temperature sensor device or associated electronic circuitry has occurred. Make
sure the sensor wire is connected.
E3 The cooling unit has malfunctioned. Contact a Service Center.
E4 DC voltage is out of range (exceeds or drops below the limit values, approximately 8-18 VDC).
Refrigerator too cold
Dislocated thermistor bracket. Clip thermistor bracket to last n on right side of cooling
ange and center vertically on n.
Dislocated thermistor bulb. Position thermistor bulb inside thermistor bracket groove and
center vertically in bracket.
If the problem persists and the refrigerator is still not working properly, turn refrigerator off and contact your nearest Service
Center. State the problem, model, product, and serial number. These details are stated on the data label inside the fresh
food compartment.