EasyManua.ls Logo

Dometic RMD10.5T - Page 19

Dometic RMD10.5T
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RMD10 Installing the refrigerator
19
4.3 Making air inlet and outlet vents
I
Make an air inlet vent and an air outlet vent in the outer wall with the size of
249 mm x 490 mm (9.8 in. x 19.29 in.).
When doing so, observe the information, see chapter “Preparing the installa-
tion” on page 16.
If the ventilation grill of the air inlet vent cannot be installed flush with the floor of the
niche, install an inlet vent in the floor. Any leaking gas can thus flow downwards.
Make an air inlet vent of at least Ø 40 mm (1.57 in.) in the floor (fig. 8 1, page 7)
behind the refrigerator near the gas burner.
Shield the end of the opening with a deflector to prevent sludge or dirt from get-
ting inside while driving (fig. 8 2, page 7).
If you have to use a roof vent instead of the air outlet vent:
Cut out a section in the roof. Refer to the roof vent instruction manual for the
required dimensions.
When doing so, observe the information in chapter “Preparing the installation”
on page 16.
4.4 Installing the ventilation grill
I
NOTE
Deviations from the inlet and outlet variations shown here must be
approved by the manufacturer.
At high ambient temperatures, the refrigerator can only provide its
maximum cooling capacity if the optimum ventilation has been pro-
vided.
NOTE
Use exclusively original Dometic ventilation grills to ensure safe
operation.
No. in
fig. 9, page 7
Description
1Slider
2 Ventilation grill
RMD10_INM_US.book Seite 19 Dienstag, 10. Dezember 2019 2:09 14

Other manuals for Dometic RMD10.5T

Related product manuals