- Page 49 of 60 -
Report No. STS200421001001E
EN 62368-1
Clause Requirement + Test Result - Remark Verdict
Shenzhen NTEK Testing Technology Co., Ltd
5.4.9 TABLE: Electric strength tests N/A
Test voltage applied between: Voltage shape
(AC, DC)
Test voltage (V) Breakdown
Yes/No
-- -- -- --
Basic/supplementary:
-- -- -- --
Reinforced:
--
-- -- --
Routine Tests:
-- -- -- --
Supplementary information:
5.5.2.2 TABLE: Stored discharge on capacitors N/A
Supply Voltage (V), Hz Test
Location
Operating
Condition (N,
S)
Switch
position
On or off
Measured Voltage
(after 2 seconds)
ES Classification
-- -- -- -- -- --
Supplementary information:
X-capacitors installed for testing are: --
bleeding resistor rating: --
ICX:
Notes:
A. Test Location:
Phase to Neutral; Phase to Phase; Phase to Earth; and/or Neutral to Earth
B. Operating condition abbreviations:
N – Normal operating condition (e.g., normal operation, or open fuse); S –Single fault condition
OC- Opened circuit
5.6.6.2 TABLE: Resistance of protective conductors and terminations N/A
Accessible part Test current
(A)
Duration
(min)
Voltage drop
(V)
Resistance
(Ω)
-- -- -- -- --
Supplementary information:
5.7.2.2,
5.7.4
TABLE: Earthed accessible conductive part N/A