3.5 Hold Feature Operation
The relay hold feature allows a set of four-digit entry codes to latch (or hold) a relay indefinitely. Any four-digit entry code that
falls numerically within the hold boundaries will cause relay 1 to activate indefinitely if no four-digit divide number is
programmed.
If a four-digit divide number is programmed, and the divide number is less than the lower hold boundary, then the four-digit
codes within the hold boundary will activate relay 2.
If a four-digit divide number is programmed, and the divide number is greater than the upper hold boundary, then the four-digit
codes within the hold boundary will activate relay 1.
If a four-digit divide number is programmed, and it falls between the hold boundaries, then four-digit entry codes equal to or
less than the divide number, but greater than the lower hold boundary, will activate relay 1 indefinitely.
Four-digit entry codes that are greater than the divide number, but less than the upper hold boundary, will activate relay 2
indefinitely. To deactivate a relay that is latched, simply re-enter the number that was used to activate the relay. See sample
charts below.
Five-digit entry codes are NOT affected by hold boundaries.
Relay 1
Relay 1 momentarily
activates with entry
code 2000 or lower.
Relay 2
Relay 2 momentarily
activates with entry
codes 2001 thru 2009.
Relay 2 latches when
entry codes 2010 thru
2015 are entered on
the keypad.
Relay 2 momentarily
activates with entry
codes 2016 and
higher.
Divide Number 2000
Lower Hold
Boundary 2010
Upper Hold
Boundary 2015
Example 1
Relay 1
Relay 1 momentarily
activates with entry
code 2009 or lower.
Relay 2
Relay 1 latches when
entry codes 2010 thru
2015 are entered on
the keypad.
Relay 1 momentarily
activates with entry
codes 2016 thru
2025.
Relay 2 momentarily
activates with entry
code 2026 or
higher.
Divide Number 2025
Upper Hold
Boundary 2015
Lower Hold
Boundary 2010
Example 2
Relay 1
Relay 1 momentarily
activates with entry
code 2009 or lower.
Relay 2
Relay 1 latches when
entry codes 2010 thru
2012 are entered on
the keypad.
Relay 2 latches when
entry codes 2013 thru
2015 are entered on
keypad.
Relay 2 momentarily
activates with entry
code 2016 and
higher.
Divide Number 2012
Upper Hold
Boundary 2015
Lower Hold
Boundary 2010
Example 3