EasyManua.ls Logo

DoorKing 1506-080 - 2.8 Programming Five-digit Entry Codes; 2.9 Erasing Individual Five-digit Entry Codes; 2.10 Erasing ALL Five-digit Entry Codes; 2.11 Five-digit Entry Code Divide Number

DoorKing 1506-080
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1506-065-F-3-14 Page 17
2.8 Programming Five-digit Entry Codes
1. Press *09 and enter the four-digit master code _ _ _ _ (short beep).
2. Enter the five-digit code _ _ _ _ _ then press * (beep).
3. Repeat step 2 to enter additional entry codes. Note: a maximum of 6 five-digit entry
codes can be programmed.
4. Press 0# together to end the programming step (long beep).
2.9 Erasing Individual Five-digit Entry Codes
1. Press *10 and enter the four-digit master code _ _ _ _ (short beep).
2. Enter the five-digit code to be erased _ _ _ _ _ then press * (beep).
3. Repeat step 2 to erase additional entry codes.
4. Press 0# together to end the programming step (long beep).
2.10 Erasing ALL Five-digit Entry Codes
CAUTION: This sequence will erase ALL five-digit entry codes that have been previously
programmed into the keypad and is irreversible.
1. Press *11 and enter the four-digit master code _ _ _ _ (short beep).
2. Press 9 9 9 9 * (short beep).
3. After approximately 10-seconds, a long beep will be heard indicating that all five-digit
entry codes have been erased.
2.11 Five-digit Entry Code Divide Number
The five-digit entry codes can be made to activate either relay 1 or relay 2 by programming a five-digit
"divide" number. Five-digit entry codes equal to or less than the divide number will activate relay 1,
while five-digit entry codes greater than the divide number will activate relay 2. If no divide number is
programmed (enter # # # # # in step 2), then relay 2 acts as an alarm by-pass relay, activating .1
second prior to relay 1, and deactivating .1 second after relay 1.
Important: Both four-digit and five-digit entry codes must be programmed to operate in the same
mode. If a divide number is programmed for the five-digit codes, then a divide number must also be
programmed for the four-digit entry codes (see page 16). The system is preset at the factory with no
divide numbers programmed.
1. Press *13 and enter the four-digit master code _ _ _ _ (short beep).
2. Enter a five-digit divide number _ _ _ _ _ then press * (short beep).
3. Press 0# together to end the programming step (long beep).
Note: To delete the five-digit entry code divide number, enter # # # # # in step 2. This will cause relay
2 to act as an alarm by-pass relay provided that the five-digit divide number has also been deleted