2358-065-L-7-16
10
Optional quad box enclosure (P/N 2351-081) provides a lockable weather resistant housing for up to four (4) tracker expansion boards.
Includes four (4) terminals and four (4) convenience outlets for power transformers. You may power up to four (4) tracker expansion boards
from a Single 16.5 VAC, 50 VA power transformer (P/N 1508-060). See section 3.9 for quad box wiring information.
2.2 Quad Board Enclosure
4”
3.5”
7”
2.75”
24”
14”
2” 2”
Conduit Placement
Options
(5) 8-Pin Terminals
Communication
Lines
Terminal
Access Point TerminalAccess Point Terminal
Access Point TerminalAccess Point Terminal
Mounting Hole Mounting Hole
Mounting HoleMounting Hole
Tracker
Expansion
Board
Mount
Tracker
Expansion
Board
Mount
Tracker
Expansion
Board
Mount
Tracker
Expansion
Board
Mount
3/4”
3/4” 3/4”
3/4” 3/4”
3/4”
2” 2.5” 2.5” 2.5”
3/4”
3/4”
3/4”
3/4”
3/4”
3/4”
3/4”
3/4”
4”
1”
1”
1”
3/4” Conduit 3/4” Conduit
3/4” Conduit
1” Conduit
1”
Conduit
3/4”
Conduit
Note: Remove convenience outlets power plate
to access knock-outs and mounting hole.
Note: Conduit entering in back of housing
knock-outs
knock-outs
knock-outs
Back of Housing
Battery Back-Up Note:
A 12 VDC, 3 amp-hour battery
(P/N 1801-009) can be used to
supply back-up power to four
(4) tracker expansion boards.
Optional single enclosure (P/N 2351-080) provides a lockable, weather resistant housing for a single tracker expansion board.
2.1 Single Board Enclosure
Tracker
Expansion
Board
Mount
3/4”
Conduit
Placement
1” 1”3.75”
1.25”
2.375”
3/4”
Knock-outs
Mounting Hole
Battery Back-Up Note:
A 12 VDC, .8 amp-hour battery
(P/N 1801-008) can be used to
supply back-up power to a
single tracker expansion board.
Important Wireless Note: DO NOT remove antenna plugs if
NOT using a antenna that screws into the top of the enclosure
for wireless communication.
If using an external antenna for wireless communication that
uses a coax cable, run it out of the BOTTOM of the enclosure.
DO NOT run coax cable out of the top of the enclosure, it will
leak and cause damage to the circuit board.
8.75”
5.75” 3.625”
Mounting Hole
Optional Screw On Antenna Mounts
for wireless kits ONLY.