What to do if Overload Alarm #2009 is active on Doosan Sander?
- JJohn JonesAug 1, 2025
If the Overload Alarm #2009 is active on your Doosan Sander, try toggling the power off and then on again to release the alarm.
What to do if Overload Alarm #2009 is active on Doosan Sander?
If the Overload Alarm #2009 is active on your Doosan Sander, try toggling the power off and then on again to release the alarm.
How to recover Arm Home Position on Doosan Sander after power interruption before unclamp or after clamp?
If you experience a power interruption before unclamping or after clamping with your Doosan Sander, use the Reverse Step Control to recover the Arm Home Position.
What to do if power interruption occurs during arm driving before clamp on Doosan Sander?
If a power interruption occurs during arm driving before clamping on your Doosan Sander, use the Reverse Step Control to recover the Arm Home Position.
Why is #2065 Alarm activated on Doosan Sander?
If the #2065 Alarm is activated on your Doosan Sander, it may be because the Cam Follower Bearing is not properly positioned in the center area. Verify the Cam Follower Bearing location, and then release the #2065 Alarm by Origin Initialization from the Servo Drive.
What to do if power interruption occurs during unclamp or right after clamp on Doosan Sander?
If a power interruption occurs during unclamping or right after clamping on your Doosan Sander, use the Reverse Control.
How to fix Faulty S/W and Dog alignment on Doosan Sander?
If you have faulty S/W and Dog alignment on your Doosan Sander, reorder the Switch, secure it, and then Initialize.
What to do if Normal S/W and Dog alignment with Faulty Cam Follower on Doosan Sander?
If you have normal S/W and Dog alignment but a Faulty Cam Follower on your Doosan Sander, realign the Changer Arm using Inching, reorder the Switch, and then Initialize.
Brand | Doosan |
---|---|
Model | HP5100 |
Category | Control Unit |
Language | English |
Steps to take for the servo alarm.
Procedures to resolve circuit protector trips.
Steps for operating the ATC in manual mode.
Procedures to troubleshoot the AL2065 alarm.
Troubleshooting steps for ATC arm driving case '1'.
Process for troubleshooting jammed machines.
Steps to resolve and recover from M06 command overtime.
Recovery steps for arm stop during tool clamp.
Troubleshooting for common alarm codes.
Steps to resolve commanded status issue.
Status and causes of VPF off alarm.
Procedures to resolve VPF off alarm.