Questions and Answers

  • P
    phouseAug 12, 2025
    Why is my Doran 8000XLM reading bouncing?
    • J
      Jeffrey StephensAug 12, 2025
      If your Doran scale's readings are unstable or fluctuating, it might be due to air currents or vibrations. To stabilize the reading, try increasing the Digital Averaging setting.
  • C
    Carlos DeanAug 17, 2025
    What to do if Doran 8000XLM Scales will not come to zero?
    • S
      shannon85Aug 17, 2025
      If your Doran scale doesn't return to zero when the ZERO button is pressed, ensure the scale is stable (the "MOT" annunciator is off). If excessive motion is a problem, activate the latching POd Avg C32 print feature or lengthen the filter time. If the scale is stable, but it still doesn't work, it may be a problem with the touch-panel or main board.
  • S
    stephen82Aug 23, 2025
    How to check if Doran 8000XLM Scales weight readings are correct?
    • T
      tristanharveyAug 23, 2025
      If your Doran scale's weight readings seem incorrect, verify its accuracy using a test weight. If necessary, recalibrate the scale.
  • J
    janet62Aug 30, 2025
    Why does my Doran 8000XLM Scales drift off of zero?
    • M
      Marcia SullivanAug 30, 2025
      If your Doran scale drifts off zero, it may be caused by air currents or vibration. To compensate, try setting the AZT aperture to a wider setting.
  • U
    upearsonSep 5, 2025
    What to do if Doran Scales overloads early?
    • C
      Chelsea HowardSep 5, 2025
      If your Doran scale overloads early, it's possible that the scale is being shock-loaded, causing the load cell to shift. Ensure all four corner overload stops are properly set, if present. To check the stops, take the platter off the scale, invert it and place it back on the spider. With 1/2 of the scale's capacity in test weights concentrated over a corner of the platform, there should be approximately 1/32" of clearance between the stop and the bottom of the spider. Check all four corners, then recalibrate the scale.

Doran 8000XLM Specifications

General IconGeneral
Capacity1000 lb (450 kg)
Platform Size19 x 28 inches
PowerBattery or AC adapter
Accuracy0.1% of full scale
DisplayLCD