53
Remote Operation
7.5.4 SYST:SCREENSAVER?
Syntax
SYSTem:SCREENSAVER?
Description
This command will return the screen saver time settings n (n is in minutes).
Possible values for n are 0, 2, 3, 4, 5, ……
Note that 1 is not a valid value.
0 = Screen saver is disabled
Possible error codes
5
Factory default value
5
Power on behavior
Keeps last value
*RST effect
None
7.5.5 SYST:SCREENSAVER x
Syntax
SYSTem:SCREENSAVER x
Description
This command will set the screen saver time settings x (x is in minutes).
Possible values for x are 0, 2, 3, 4, 5, ……
Note that 1 is not a valid value.
0 = Screen saver is disabled
Possible error codes
5
Factory default value
5
Power on behavior
Keeps last value
*RST effect
None

Table of Contents