Safety instructions
5
Health / Hygiene / Environment
Solvent-resistant gloves and safety goggles are recommended
during cleaning operations.
Please read the Isopropanol Safety Data Information prior to using
Isopropanol with any Markem-Imaje product.
Noise levels:
Test Standard BS EN ISO 3746:1996
SmartDate X60 Intermittent Mode 199 ppm with a 10 mm Image
(700 mm/s) <70 dB (A)
SmartDate X60 Continuous Mode 299 ppm with a 10 mm Image
(160 mm bag) (800 mm/s) 70 dB (A)
Operating environment of:
32o F to 104o F(0o C to 40o C)
Installation Requirements
The printer must be placed such that all its surfaces are easily
accessible and the control interfaces are fully visible.
Ensure that these services and control signals are available:
Power - 100 - 230V AC (+/- 10%) 50 - 60 Hz
Compressed Air - 6 Bar (max.), dry and uncontaminated.
A Print Go Signal - This can be either a volt free contact which
closes when printing is required, or a 24 V DC signal from a PNP
sensor (positive edge triggered).
Sufcient space for installation and operation.
SmartDate X60 congured as a continuous printer also requires
an encoder to monitor the substrate speed.