For your safety and that of your patients
12 Instructions for use Oxylog 3000 plus SW 1.n
Product-specific safety information
Installing accessories
Strictly follow the assembly instructions and
instructions for use.
Only one copy of the instructions for use
available
WARNING
Ventilation monitoring is mandatory at all
times! Whenever a patient is connected to the
ventilator, constant attention by qualified
medical staff is required in order to provide
immediate corrective action in case of a mal-
function.
The user must not solely rely on the built-in
monitoring of the ventilator and must always
assume full responsibility for proper venti-
lation and patient safety in all situations.
WARNING
Keep a manual resuscitator at the ready
If a failure is detected in the ventilator and its
life-support functions can no longer be guar-
anteed (e.g., in case of a power supply failure
or interruption in the gas supply), ventilation
must immediately be started with an indepen-
dent ventilation device (breathing bag) – using
PEEP and/or increased inspiratory O
2
concen-
tration as necessary.
WARNING
Risk of CO2 rebreathing
To ensure proper ventilation when setting the
ventilation parameters, the total dead space
volume of the breathing circuit must be con-
sidered. This applies particularly when using
low tidal volumes. Observe for signs of
rebreathing.
WARNING
Risk of malfunction
Unauthorized modification of the medical
device will result in malfunction.
This medical device may not be modified with-
out the permission of Dräger.
CAUTION
An etCO2 value by itself is insufficient as a basis
for medical decisions.
WARNING
Risk of incorrect operation and of incorrect
use
Follow the instructions for use of all accesso-
ries carefully.
CAUTION
Installations on Oxylog 3000 plus must be done in
accordance with these instructions for use. Make
sure that the connections are securely fitted onto
the basic unit system.
CAUTION
Only one copy of the instructions for use is
included per device, and it must therefore be kept
in an accessible location for users.

Table of Contents

Other manuals for Dräger Oxylog 2000 plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger Oxylog 2000 plus and is the answer not in the manual?

Dräger Oxylog 2000 plus Specifications

General IconGeneral
BrandDräger
ModelOxylog 2000 plus
CategoryMedical Equipment
LanguageEnglish

Related product manuals