AC Voltage
Range Accuracy Resolution
200mV 0.1mV
2V ±0.8% rdg + 5 digits 0.001V
20V 0.01V
200V 0.1V
600V ±1.0% rdg + 5 digits 1V
DC Current
Range Accuracy Resolution
2A 0.001A
10A ±2.5% rdg + 10 digits 0.01A
AC Current
Range Accuracy Resolution
2A 0.001A
10A ±3.0% rdg + 10 digits 0.01A
- Input Impedance: 10M
- Overload Protection:
200mV range: 250V DC or AC rms,
2V-600V ranges: 600V DC or AC rms.
- Frequency Range: 40 to 400Hz
- Max. Input Voltage: 600V rms AC
- Overload Protection: 500V/10A FUSE
- Max. Input Current:10A
- Voltage drop: 2A range: 20mV,
10A range: 100mV
- Overload Protection: 500V/10A FUSE
- Max. Input Current:10A
- Frequency Range: 40 to 400Hz
- Voltage drop2A range: 20mV, 10A range: 100mV
9.1 BATTERY REPLACEMENT
WARNING
Before attempting to open the battery cover of the meter, be sure that test leads
have been disconnected.
4. INTRODUCTION
9. MAINTENANCE