22/2
Twisted Pair
14/2
24V
MOTOR
Wall Switch
24V
Transformer
Wiring Distance to Motor
240 ft with 14AWG
150 ft with 16AWG
100 ft with 18AWG
Controls & System Overview
Sonesse 24V DC Motors
24V
MOTOR
24V
MOTOR
Wall Switch
(Max 8 Motors
per switch)
24V
MOTOR
110-120V Line
24V
Power Panel
5, 10, 15, 20
Single Dry Contact Motor
Multiple Dry Contact Motors
STOP
110V
Outlet
STOP
Dashed Wiring
by Electrician
Wiring Distance to Motor
240 ft with 14AWG
150 ft with 16AWG
100 ft with 18AWG
Controls & System Overview
Sonesse 485 - 24V DC Motors
Multiple 485 Motors
Dashed Wiring
by Electrician
14/222/2
Twisted Pair
Wall Switch
(Max 8 Motors
per switch)
STOP
110V
Outlet
Bus Power
Supply
24V
MOTOR
24V
MOTOR
24V
MOTOR
110-120V Line
24V
Power Panel
5, 10, 15, 20
24V
MOTOR
24V
Transformer
Wiring Distance to Motor
240 ft with 14AWG
150 ft with 16AWG
100 ft with 18AWG
Controls & System Overview
Sonesse RTS 24V DC Motors
Single RTS Motor
Multiple RTS Motors
110V
Outlet
Dashed Wiring
by Electrician
Deco Flex
Wireless Keypad
Telis 1
RF Remote
STOP
Deco Flex
Wireless Keypad
(Max 8 Motors
per switch)
Telis 1
RF Remote
STOP
14/222/2
Twisted Pair
24V
MOTOR
24V
MOTOR
24V
MOTOR
110-120V Line
24V
Power Panel
5, 10, 15, 20
Motorized FlexShade
®
with ST30 24V DC Operator
(RTS Shown)
Fascia
Endcap
Cover (R)
Brackets
Only (L)
Brackets
Only (R)
Endcap (R)
for Fascia
Endcap (L)
for Fascia
Antenna
Endcap
Cover (L)
Power
Cable
Retainer
Clip