GTS
®
Gas-to-Steam Humidifier
LX Series
Installation, Operation,
and Maintenance Manual
READ AND SAVE THESE INSTRUCTIONS
WARNING
Fire or explosion hazard
If the information in this manual is not
followed exactly, a fire or explosion could
result, causing property damage, personal
injury, or death.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
If you smell gas:
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from an off-site phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier,
call the fire department.
Installation and service must be performed
by a qualified installer, service agency, or
the gas supplier.
For toll-free support call DriSteem Technical
Support: 1-800-328-4447

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the DriSteem GTS LX-100 and is the answer not in the manual?

DriSteem GTS LX-100 Specifications

General IconGeneral
Water Connection1/2" NPT
DispersionSteam
Steam Pressure0 psi (0 bar)
Electrical208-240V, 380-480V, 575-600V
Voltage208-600V
Weight250 lbs (113 kg)

Summary

INSTALLATION

Location and Clearance Recommendations

Guidelines for selecting an appropriate installation site, considering safety and clearances.

Wiring

Guidelines and safety precautions for electrical wiring and grounding.

PIPING AND CONNECTIONS

Piping: Connection Sizes

Table detailing required pipe connection sizes for various models.

Piping: Supply Water and Drain

Specifics on supply water requirements and drain piping configuration.

Piping: Gas

Guidelines, safety, and pressure requirements for gas piping.

GENERAL VENTING

Room Air Combustion

Guidelines for providing adequate combustion air from room air.

Sealed Combustion

Requirements for sealed combustion using outside air supply.

OPERATION

Start-up Checklist

A comprehensive checklist for verifying installation and preparing for initial operation.

Start-up Procedure

Detailed steps for initiating the humidifier's operation and performing initial checks.

MAINTENANCE

Inspection Recommendations

Guidelines for regular user and annual inspections of the humidifier.