Bellavita Fault Finding Page 1 of 2 Issued 08/12
FAULT FINDING BELLAVITA BATHLIFT
In the event of the Bellavita not working, the following steps should be taken.
Please follow the steps below to attempt a remedy:
1. Test the PCB board. To do this:
i. Ensure the handset is switch off by pressing the red button.
ii. Hold down the UP and DOWN together.
iii. Whilst they are pressed down, press the ON button and release all buttons.
iv. The LED should light orange and flash.
v. Press the UP button and you should hear a click.
v
i. Press the DOWN button and you should not hear a click
vii. If the handset does not behave as described above then a PCB fault is present.
viii. OPTIONAL: If you press the DOWN and ON button together, the bathlift will
lower even if the red light is showing (assuming handset is working correctly).
2. Try to reset the handset. Repeat step 1 twice to reset the handset.
3. If the fault is still present after steps 1 and 2 then check the bathlift operation with
another Bellavita handse
t. If the bathlift still does not work then this is likely to be a fault
with the Bathlift backrest, and will require replacement from Drive Medical. If Bathlift is
stuck partially or fully upright, follow the attached instructions to disassemble the
backrest. If the handset works with the alternative handset, replace the faulty handset.
Spare Parts Available
460 900 600: Handset
460 900 402: UK Charger
460 900 700: Backrest Kit (includes motor, drive ram and backrest)
Question and Answer IconNeed help?

Do you have a question about the Drive Bellavita and is the answer not in the manual?

Drive Bellavita Specifications

General IconGeneral
BrandDrive
ModelBellavita
CategoryBathroom Aid
LanguageEnglish

Summary

Bellavita Bathlift Fault Finding

PCB Board Testing Procedure

Detailed steps to test the PCB board for faults by checking LED and button responses.

Handset Reset Process

Instructions to reset the handset by repeating the PCB test procedure twice.

Troubleshooting with Alternative Handset and Backrest

Steps to check bathlift operation with another handset and diagnose backrest issues.

Available Spare Parts

List of spare parts including handset, charger, and backrest kit.

Bellavita Bathlift Disassembly Guide

Laying and Preparing for Disassembly

Initial step to lay the bathlift on its side before proceeding with disassembly.

Backrest Screw Removal

Instructions for removing backrest screws using a T-20 end bit and screwdriver.

Detaching Backrest and Lifting Ram

Steps to pull the backrest away and remove the lifting ram and faulty backrest.

Disassembly Authorization and Return Policy

Note on gaining authorization before disassembly and returning the bathlift for reassembly.