DPI 610E
DPI 610E-IS
Portable Pressure Calibrator
Instruction Manual
DPI 610E-PC DPI 610E-SPC
DPI 610E-HC DPI 610E-SHC

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Druck DPI 610E and is the answer not in the manual?

Druck DPI 610E Specifications

General IconGeneral
Pressure MediaNon-corrosive gases and liquids compatible with 316 stainless steel
TypePressure Calibrator
Pressure Unitspsi, bar, kPa, MPa, inHg, mmHg, mbar
Current Measurement0 to 24 mA
Voltage Measurement0 to 30 V
Power SupplyRechargeable battery or external power supply
DisplayBacklit LCD
Data LoggingYes
CommunicationUSB
Operating Temperature-10°C to 50°C (14°F to 122°F)
Storage Temperature-20°C (-4°F)
Dimensions100 mm (3.9 in)

Summary

1. Overview

1.1 DPI 610E Series

Overview of the DPI 610E Series instruments, including models and firmware.

1.2 Equipment in the Box

Details the items included with the DPI 610E instruments.

1.3 Specifications for DPI 610E

Provides technical specifications for the DPI 610E calibrator.

1.4 Accessories

Lists common accessories available for the DPI 610E series.

1.6 Safety

General safety precautions and warnings for instrument operation.

1.7 Maintenance

Outlines maintenance tasks, service procedures, and repair information.

1.8 Service and Repair

Information on authorized service and repair providers.

1.10 Instrument Return

Steps for returning the instrument for calibration or service.

1.13 Battery and Charging

Covers instrument battery status, charging, and power controls.

1.15 Parts

Details the various parts of the DPI 610E instrument.

1.17 User Interface

Explains the instrument's user interface, buttons, and dashboard navigation.

1.19 Dashboard

Navigating the instrument's main dashboard and its features.

2. Pump Operations

2.1 Pneumatic System

Detailed instructions for operating the pneumatic pump system.

2.2 Hydraulic System

Instructions for operating the hydraulic pump system.

3. Basic Tasks

Tasks Overview

Introduction to tasks and their configuration on the instrument.

Task Selection

How to select and initiate a task from the menu.

Adding/Removing Tasks from Dashboard

Managing shortcuts for tasks on the dashboard screen.

4. General Settings

Date, Time, and Language Configuration

How to set the instrument's date, time, and language preferences.

Backlight Settings

Adjusting the screen backlight for optimal viewing.

USB Communication Settings

Configuring the USB connection mode for data transfer.

Auto Power Down Setting

Configuration of the instrument's auto power down feature.

Touchscreen Lock

Feature to lock the touchscreen for controlled navigation.

Enable Hold Function

Option to enable or disable the Hold function on the main screen.

5. Advanced Menu

CALIBRATION Menu Access

How to access the instrument calibration menu.

CHANGE PIN

Procedure to change the advanced menu PIN.

SOFTWARE UPGRADE

Steps for loading and upgrading the instrument's firmware.

FACTORY RESET

How to reset the instrument to its factory default settings.

6. Calibrator Tasks

Calibrator Task Screen Overview

Explanation of the elements on the Calibrator Task screen.

Maximize and Minimize Channel Window

How to adjust the display layout of the channel windows.

Change Measurement Units

Procedure to change the units displayed for channel measurements.

Error Indications

Understanding and interpreting out-of-range error messages.

Available Functions by Channel

Lists functions available for CH1 and CH2 with combination matrix.

Pressure Measurement Configuration

How to configure internal and external pressure measurements.

Sum and Difference Functions

How to use Sum and Difference functions for pressure readings.

Current Measurement and Source

How to measure and source electrical current using CH2.

Voltage and Millivolts Measurement

How to measure voltage and millivolts using CH2.

HART Communication Protocol

How to set up and use the HART communication protocol.

Process Options (Tare, Min/Max/Mean, Filter)

Configuration of process options like Tare, Min/Max/Mean, and Filter.

Flow and Alarm Functions

How to enable Flow and Alarm functions for channel readings.

Scaling Function

Method for configuring custom measurement units using scaling.

7. Utilities

7.1 Leak Test

How to perform a leak test on equipment or systems.

7.2 Switch Test

How to test pressure switches and devices with switch contacts.

7.3 TX (Transmitter Simulation) Simulator

How to simulate a pressure transmitter using current output.

7.4 Relief Valve Test

Procedure for testing vacuum relief valves.

8. External Sensors

8.1 PM700E Sensor Overview

Introduction to the PM700E external remote pressure sensors.

8.1.2 Media Compatibility

Guidelines for observing media compatibility with PM700E sensors.

8.1.3 Setup

Steps for connecting and setting up PM700E sensors.

8.1.5 Available External Pressure Sensors

Lists compatible external pressure sensors for the DPI 610E.

8.1.6 Configuration of an External Pressure Sensor

Steps to configure a channel with an external pressure sensor reading.

8.2 RTD Probe and Interface

Information on connecting and using RTD probes and interfaces.

8.2.4 Configuration of a channel for a RTD sensor

How to configure channels for RTD sensor measurements.

8.2.5 RTD Profiles

Details on setting up and copying RTD profiles.

9. Data Log

Data Log Setup Menu

Options for configuring data logging parameters.

Setting the Data Log Filename

How to change the default filename for data log files.

Trigger Menu Options

Selecting data log trigger modes (Key Press, Periodic).

Periodic Trigger Options

Configuring time interval, duration, and data points for periodic logging.

Setting up Manual Data Logging

Steps for initiating and controlling manual data logging.

Setting up Periodic Data Logging

Steps for initiating and controlling periodic data logging.

Viewing & Deleting Data Log files

How to view, delete, or transfer data log files.

10. Analysis

10.1 Overview

Introduction to the Analysis application for calibrating transfer characteristics.

10.2 Analysis Setup

How to start the Analysis application and configure channels.

10.3 Function

Setting up input/output functions, start/end values, and linearity.

10.3.3 ERROR TYPE

Calculating and defining error types for analysis.

10.3.4 TOLERANCE

Defining tolerance limits for calculated result error.

11. Documenting

11.1 Overview

Introduction to the Documenting application for calibration records.

11.2 INTERNAL PROCEDURES

How to select and manage internal test procedures.

11.2.2 How to create an Internal Procedure

Steps for creating new internal test procedures.

11.2.5 Additional Data Required

Entering DUT, environment, and user ID details for tests.

11.3 The Documenting Main Screen

Description of the components on the Documenting Main screen.

11.5 Example Testing Session

A step-by-step example of a testing session.

11.9 How to View Test Results.

How to view As-Found and As-Left calibration results.

12. HART

12.1 HART® Connection

How to connect and establish HART communication with devices.

12.2 HART Device Configuration

Configuring the HART device, including poll address and range.

12.3 HART Dashboard

Navigating the HART dashboard and accessing device information.

12.4 HART Service Methods

Performing HART service methods like Loop Test and D/A Trim.

13. Instrument Calibration

13.1 How to show the Instrument Calibration screen

Steps to navigate to the instrument calibration menu.

13.2 PERFORM CALIBRATION

Detailed steps for calibrating electrical and pressure functions.

13.2.2 Calibration - Internal Pressure Sensor

How to calibrate the instrument's internal pressure sensor.

13.2.3 Calibration – Internal Barometer

Steps for calibrating the instrument's internal barometer.

13.8 EXTERNAL PRESSURE SENSOR CALIBRATION MENU

Menu for calibrating external pressure sensors.

13.8.1 PERFORM CALIBRATION

Steps to calibrate the external PM700E pressure sensor.

13.8.3 SET CALIBRATION DATE & INTERVAL

Setting calibration dates and intervals for external sensors.

13.9 EXTERNAL RTD SENSOR CALIBRATION MENU

Menu for calibrating external RTD sensors.

13.9.1 PERFORM CALIBRATION

Steps to calibrate external RTD sensors.

13.9.2 SET CALIBRATION DATE & INTERVAL

Setting calibration dates and intervals for external RTD sensors.

14. File System

14.1 How to access the Files system menu

Steps to navigate and access files stored on the instrument.

14.2 Calibration

Managing calibration files, including export and types.

14.3 Data Log

Viewing, deleting, and managing data log files.

14.5 Leak Test

Viewing and deleting saved leak test results.

14.6 Switch Test

Viewing and deleting saved switch test results.

14.7 Relief Valve

Viewing and deleting saved relief valve test results.

14.8 How to view the File System on a PC

Accessing instrument files on a PC via USB connection.

15. Status Menu

15.1 Status Menu Options

Overview of the information available in the Status menu.

15.2 How to show the Status menu screen

Steps to access the Status menu from the Dashboard.

15.3 SOFTWARE BUILD

How to view installed software build versions.

15.4 CALIBRATION

Viewing calibration status for instrument and sensors.

15.5 BATTERY

How to check the current instrument battery level.

15.6 MEMORY

How to view the instrument's internal memory usage.

15.7 SENSOR

How to view details of the instrument and external sensors.

15.8 ERROR LOG

How to export and view operational software or firmware errors.

15.9 EVENT LOG

How to export and view significant instrument events.