[10] Maintenance Alarms and Restorals
Page 12
For automatic test code reporting, time between reports (in days) must be specified in Section [17], and time of
day for the report must be entered in Section [19].
Low Battery Alarm
AC Fail Alarm
Fuse Failure Alarm
Low Battery Restore
AC Fail Restore
Fuse Failure Restore
Automatic Test Code
[11] Zone Definitions
Page 12
NOTE: When defining zones, assign delay zones first to zones 1,2,3..., then assign the other zone types to the
remaining zones in any order desired.
Default
0 0 Zone 1
0 1 Zone 2
0 1 Zone 3
0 2 Zone 4
0 2 Zone 5
0 8 Zone 6
First Digit Second Digit
0 = Slow, Audible 0 = Standard Delay
1 = Slow, Silent 1 = Instant
2 = Fast, Audible 2 = Interior
3 = Fast, Silent 3 = Interior, Home-Away
4 = 24 Hour Bell
5 = 24 Hour Bell/Buzzer
6 = 24 Hour Buzzer
7 = Aux. Delay (Uses Auxiliary
Entry/Exit Times)
8 = Fire
Any one zone may be set as a FIRE zone.
[12] 1st System Option Code
Page 13
Default Zone Light ON Zone Light OFF
OFF Zone Light 1 Communicator disabled Communicator enabled
OFF Zone Light 2 TX limit to 24 hour period TX limit to armed period
ON Zone Light 3 Alarm display while armed No alarm display while armed
ON Zone Light 4 DTMF dialling Pulse dialling
OFF Zone Light 5 N.C. loops (except fire) EOL resistor loops
ON Zone Light 6 Keypad [P]anic audible (bell) Keypad [P]anic silent (bell)