23
PC1510 Version 4.1
[13] 2nd System Option Code
Page 14
Default Zone Light ON Zone Light OFF
ON Zone Light 1 Call 1st phone only Backup to 2nd phone
11
11
1
OFF Zone Light 2 Master Code not changeable Master Code changeable
OFF Zone Light 3 Bell Squawk enabled
22
22
2
Bell Squawk disabled
OFF Zone Light 4 PC16 OUT enabled PC16 OUT disabled
OFF Zone Light 5 6th code is maids code 6th code normal
OFF Zone Light 6 1400 Hz Radionics 2300 Hz Radionics
11
11
1
Do not program OFF unless 2nd phone number is programmed.
22
22
2
With Bell Squawk enabled, the bell/siren will sound one short burst on arming and two short bursts on
disarming.
[14] 3rd System Option Code
Page 14
Default Zone Light ON Zone Light OFF
OFF Zone Light 1 User code required for bypass Code not required
OFF Zone Light 2 [
] [4] Enabled [
] [4] Disabled
OFF Zone Light 3 Periodic downloading Periodic test transmit
OFF Zone Light 4 [
] [4] access code required [
] [4] no code required
ON Zone Light 5 [P]anic audible (buzzer) [P]anic silent (buzzer)
OFF Zone Light 6 Partial closing identified Not identified
[15] Communication Variables
Page 14
Default
0 3 Maximum transmissions per burglary zone
Enter digits from 01 to 99 for number of transmissions per zone during the period as defined in Section [12],
1st System Option Code, Zone Light 2. Note that 00 = unlimited transmissions per burglary zone.
Fire zone
always transmits.
Default
0 0 Delay before transmission (burglary zones only)
Enter digits from 01 to 99 - delay in seconds; 00 = no delay.
Fire zone and 24 hour zone transmissions
cannot be delayed.
Transmission delay as programmed here is for burglary zones only.