26
PC1510 Version 4.1
[24] Programmable Output Options (PGM Terminal)
Page 16
Enter 2 digits from 01 to 0C only.
Default
0 4 Programmable Output [01] Ground Start Pulse
[02] Utility Output, No Access Code - 5 seconds [
] [7]
[03] Utility Output, Any Access Code - 5 seconds [
] [7]
[04] 5 Second Reset Pulse [
] [7]
[05] Courtesy Pulse (follows entry/exit times)
[06] Keypad Buzzer Follow Mode
[07] System Status (arm/disarm) Output
[08] Strobe Output (latched alarm output)
[09] Failure to Communicate Output - follows trouble #4
[0A] PGM ON during Entry Delay
[0B] PGM ON during Exit Delay
[06] Buzzer follows the entry delay, door chime, auto-arm alert
period and 24 hour buzzer loop.
[25] Communicator Call Directions
Page 17
This section must be completely programmed. Do not press [#] to exit until all entries are completed.
Default
1 Zone Alarms and Restorals [0] No transmissions for this group.
1 Access Code Openings and Closings [1] Call 1st number and backup to 2nd number.
1 Priority Alarms and Restorals [2] Call 2nd phone number only.
1 Maintenance Alarms and Restorals [3] Always call both phone numbers.
Section [13] Light 1 OFF and 2nd phone number must be programmed.
[26] Downloading Telephone Number
Page 17
This telephone number is used by the panel to call the downloading computer either by the periodic download
function or through the use of the [
] [4] command.
Enter [0] for the digit 0 in the phone number. Enter [
4
] (HEX D) for additional dial tone detection between
number digits, as in local PBX systems. Enter [#] to end the phone number entry.
[27] Downloading Access Code
Page 17
Default
1515
This code allows the panel to confirm that a valid downloading computer is requesting access to the panel.
[28] Panel Identification Code
Page 17
Default
1501
This code confirms the panels identity to the downloading computer.