17
PC1550 Version 4.1
[15] Communication Variables
Page 11
Default
NOTE:
For UL installations, the Maximum Transmissions section cannot be enabled. Also, the Delay Before Transmission
must not exceed 15 seconds.
0 3 Maximum transmissions per burglary zone
Enter digits from 01 to 99 for number of transmissions per zone during the period as defined in Section [12], 1st System
Option Code, Zone Light 2. Note that 00 = unlimited transmissions per burglary zone.
Fire zone always transmits.
Default
0 0 Delay before transmission (burglary zones only)
Enter digits from 01 to 99 - delay in seconds; 00 = no delay.
Fire zone and 24 hour zone transmissions cannot be
delayed.
Transmission delay as programmed here is for burglary zones only.
[16] Zone Bypass Mask
Page 11
If the zone light is ON, the zone can be bypassed using the [][1] command. If a zone is defined as a fire zone, it cannot
be bypassed.
Default Default
ON Zone Light 1 ON Zone Light 4
ON Zone Light 2 ON Zone Light 5
ON Zone Light 3 ON Zone Light 6
[17] System Times
Page 11
Default Default
0 3 0 Entry Delay (seconds) 0 3 0 AC fail transmission delay (minutes)
1 2 0 Exit Delay (seconds) 0 5 0 Slow loop response time ( x 10 ms)
0 0 4 Bell Cut-off (minutes) 0 3 0 Test transmission cycle or auto download
cycle time (days)
Valid entries are 001 to 255.
Do not enter 000.Do not enter 000.
Do not enter 000.Do not enter 000.
Do not enter 000.
[18] Auxiliary Delay Loop Entry / Exit Times
Page 12
Default
0 4 5 Entry Time (seconds)
1 2 0 Exit Time (seconds) Valid entries are 001 to 255.
[19] System Clock Times
Page 12
Default
9 9 9 9 Automatic Arming (time of day)
9 9 9 9 Test transmission or auto download (time of day)
Enter 4 digits - 00 to 23 hours; 00 to 59 minutes. If a feature is not used, leave at the default setting of 9999.
For Sections [20], [21] and [22]: Enter 4 digits from “0” to “9”. Do not enter [
] or [#].
[20] New Installer’s Code
Page 12
Default
1500
[21] New Master Code
Page 12
Default
1234
[22] 2nd Master Code
Page 12
Default
A A A A The 2nd Master Code can be erased by entering [1111]. AAAA = not programmed