Resetting Programming to the Factory Default Settings
The system may be reset to its factory default programming by following this procedure:
1 Remove all power, AC and battery, from the PC560
2 Remove all wiring connections from the PGM and Zone 1 terminals
3 Connect the PGM and Zone 1 terminals together
4 Apply power to the PC560 and wait for 10 seconds
5 After approximately 10 seconds, the keypad sounder will beep and Zone Light 1 will come ON
6 Remove all power, AC and battery, from the PC560
7 Remove the connection between the PGM and Zone 1 terminals
8 Re-connect original wiring to the PGM and Zone 1 terminals
9 Restore power to the PC560; the Programming Sections have now been restored to the factory
default settings