Check-adjust ○ · Spark plug
Replace ○
Spark arrester Clean ○
· Idle speed Check-adjust ○(2)
· Valve clearance Check-adjust ○(2)
· Combustion chamber Clean After every 500Hrs. (2)
· Fuel tank and filter Clean ○(2)
· Fuel tube Check Every 2 years (Replace if necessary) (2)
·Emission related items.
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by an authorized generator dealer, unless the owner has the proper tools and is
mechanically proficient. See the Shop Manual.
(3) For commercial use, long hours of operation to determine proper maintenance intervals.
MAINTENANCE
ENGINE OIL CHANGE
Drain the oil while the engine is warm to assure rapid and complete draining.
1. Remove the drain plug and sealing washer, remove the oil filler cap, and drain the oil.
2. Reinstall the drain plug and sealing washer. Tighten the plug securely.
3. Refill with the recommended oil (see page 11) and check the oil lever.
-
- 30 -
Oil capacity:
0.6l (0.65US qt)