- 41 -
3. Keep the fixing board to the edge of opposite side of poles.
4. Spin the M6 nut on the tie rod and reinforce it.
5. Connect the anode wire on the anode pole and cover the red rubber lagging on the anode pole. Connect the
negative wire on the negative pole and cover the black rubber lagging on the negative pole.
Battery use notice:
NOTICE
1. The specification of battery recommended: 12V, 36AH
ASSEMBLY OF
PARTS
2. Don’t connect the anode and negative pole erroneously, when use the battery.
3. The battery need to be injected electrolyte before use.
4. The height of electrolyte need to be inspected each month. When the height is low, please inject distilled
water or pure water between upper level and low level (Don’t use electrolyte and tap water).
5. The battery need to be clean. If the electrolyte is spattered on the generator set, the grounding and
down-lead will be eroded. Please wash them with water if erosion.

Related product manuals