TECHNICAL DATA
IMPORTANT NOTES
DO NOT install the system facing a
mirror or any other electronic system
operated by infared sensors.
To prevent reflection problems, it
is reccomended to keep a minimum
distance of 1500mm between the sensor
and any other objects.
Before installation, flush supply pipes
and ensure that they are clean and free
from debris.
Shut off water supply prior to
installation
A backflow prevention device which
meets the requirements of Fluid
Category 5 must be fitted downstream
of the solenoid valve.
Installation of the mains adaptor must
be carried out and checked by a qualified
electrician.
During installation do not expose the
electronics to fluids, dust, dirt or damp.
DO NOT use steel wool or cleansing
agents containing alcohol, acid,
abrasives, or the like.
For surface cleaning of the sensor
use ONLY soap and water, then wipe
dry with a clean cloth or towel. When
cleaning bathroom tiles, the taps should
be protected from splashing of harsh
cleansers.
Power Supply
9V lithium battery
(not included) or
transformer
Operating Water
Pressure
0.5 - 8 bar
Sensor range
300-800mm. Preset
to 600mm
Auto Flush
Automatic hygiene
ush every 24 hrs
Preset Flush Time 6 secs
Ø30mm
HEIGHT
1.2 - 1.5m
FRONT
BACK
1