EU heat pumps
4
2. Specifications
2.1 Technical data sheet
Unit
Model
EU 70
EU 100
EU 140
EU 195
kW
7
9,8
14,3
19,6
Heating Capacity A25./W25
BTU/h
23900
33450
48500
66500
kW
6,8
9,5
13,5
18,6
Heating capacity A15/W25
BTU/h
23100
32400
46000
63500
kW
5,2
7,6
12,0
16,4
Cooling capacity A25/W25
BTU/h
17700
26000
41000
56000
Power Input
kW
1,2
1,71
2,46
3,44
Maximum volume
m3
30
40
60
80
Running Current
A
5,22
7,43
10,7
14,96
Max Running Current
A
6,5
9,3
13,4
18,7
COP at A25/W25
5,8
5,7
5,8
5,7
COP at A15/W25
5,3
Power Supply
V/Ph/Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Controller
Electronic control
Condenser
Titanium heat exchanger
Compressor Quantity
1
1
1
1
Compressor type
rotary
rotary
rotary
Scroll
Refrigerant
R410a
R410a
R410a
R410a
High air flow
M3/h
2100
2100
2300
3200
Low air flow
M3/h
1800
1800
2000
2700
Fan quantity
1
1
1
1
Fan Power Input
W
120
120
120
120
Fan Speed
RPM
850/750
850/750
850/750
850/750
Fan Direction
horizontal
horizontal
horizontal
horizontal
Noise
dB(A)
50
51
54
54
Water Connection
mm
50
50
50
50
Nominal Water Flow
m3/h
3
3
4,5
6,0
Water Pressure Drop (max)
kPa
10
10
10
10
Unit Net Dimensions
L/W/H
mm
905/420/650
905/420/650
905/420/650
1200/470/850
Unit Shipping Dimensions
L/W/H
mm
1030/440/700
1030/440/700
1030/440/700
1240/480/900
Net Weight / Shipping Weight
Kg
55/60
60/65
77/82
117/128
Measuring conditions: Outdoor air temp: 25°C , Inflowing water temp: 25°C, rel. humidity: 65%