Choosing the right power cord
Long or thin cords can drain the power provided to an electrical device by the generator. When
using such cords, allow for a slightly higher rated wattage requirement for the electrical device. See
table below for recommended cords based on the power requirement of the electrical device.
DEVICE REQUIREMENTS WIRE GAUGE BY LENGTH (ft.)
AMPS WATTS (120/240V) 10 25 50 100 150
5 600/1200 18 16 14 12 10
10 1200/2400 16 14 12 10 8
15 1800/3600 14 12 10 8 6
20 2400/4800 12 10 8 6 4
25 3000/6000 10 8 6 4 4
30 3600/7200 8 6 4 4 NR
40 4800/9600 6 4 4 NR NR
50 6000/1200 4 4 2 NR NR
*NR = NOT RECOMMENDED