Background
5
About this Manual
5
Qualification
5
Further Documentation
5
Technical Data and Additional Information about Installation of the Unit
6
Unit Dimensions
6
Technical Data for Vistavox S
9
Assembly Instructions
9
Remote) Exposure Switch
9
Connecting an External Status LED
10
Connecting Diagram for A07 - First and Second Generation
12
Menu Structure for the Touch Display
13
Reconstruction Computer / Vistasoft Installation
15
Application of the Reconstruction Computer
15
Hardware Requirements for Reconstruction Computer
15
Reconstruction PC (DELL) Orderable by Dürr Dental
16
Self-Procurement of a Reconstruction PC
16
Reconstruction PC (DELL) Recommended by Dürr Dental Via Bechtle Online Store
16
General Notes on the Hardware
16
Anygrabber
17
Framegrabber 3
17
Software Requirements for Reconstruction Computer
18
BIOS Settings
18
Antivirus Settings in Windows
19
Configuring Windows 10 Security Settings (Enablelua)
19
Deactivating Windows 10 Fast Start-Up
19
Vistasoft Installation
21
Vistavox Module in Vistasoft
21
Permissible Areas of Application Reconstruction PC
24
Connecting the Device to the Reconstruction Computer
25
Connection to Anygrabber
25
Connection to Framegrabber 3
26
Integration in Vistasoft
27
Steps after Initial Calibration
27
Acceleration in Vistasoft
27
Service Tool
33
Start-Up and Range of Functions
33
Method of Operation
35
Settings in the Service Tool
39
First Callibration Procedure and Setup after Initial Installation
41
Test Phantom / Calibration Case
42
Service Device Commands (Terminal)
43
Call and Range of Functions
43
Functioning
43
Common Commands
45
Output Device Parameters
45
Output Device Errors
45
Output Tube Temperature
45
Verification of the Transport Mode
45
Manual Exposure Switch Release Check
45
Laser Verification
45
Overview of Test Objects and Phantoms
46
Quality Assurance (Acceptance and Consistency Check)
46
Panoramic
46
Cbct
47
Advanced Calibration
49
Panoramic Unit
49
CBCT Unit
50
Electronic Design
53
Circuit Diagram - Generation 1
53
Circuit Diagram - Generation 2 (Incl. Ceph)
55
A01 / MCU Board
58
A02 / Power Board
58
A03 / Inverter Board
59
A04 / C-Shaped Arm Distributor Board
59
A05 / Control Unit
59
A06 / Canine Potentiometer Board
59
Sensor (Incl. Board)
60
X-Ray Tube (Incl. Board)
60
Quality Assurance
61
Panoramic
61
Cbct
65
Handling Kv Measurement and Retracting the X-Ray Tube
69
Retracting (Shooting) the Tube
69
Testing the Tube Voltage (Kv)
70
Checklists
71
Planning Vistavox Mounting / Reconstruction PC
71
Setting up the Reconstruction Computer
73
3-Year Maintenance
74
DGUV (BGV A3) Measurement
75
Troubleshooting
76
Unit Cannot be Switched on
76
Cannot Establish Connection to the Device
76
Computer Displays a Blue Screen
77
Vistasoft Delivers Error Message (at Latest When Starting Acquisition)
77
Device Makes Clattering Noise after Start Position Is Pressed on the Touchscreen
78
Reconstruction Aborts During Measurement of CBCT Dose at the Image Receiver
79
Device Goes into Acquisition-Ready State but no Exposure Takes Place
79
Acquisition Aborts after Short Period of Readiness
79
Unusual Running Noises When Opening or Closing the Temple Supports
80
In the Service Tool, the Left and Right Edges Remain at 0 Px During Calibration
80
In the Service Tool the Tilting of the Ceph Collimator Is Outside the Tolerance
82
Device Produces Noise When Starting up or Shutting down
85
Firmware Update
87
Reading out the Current Version Statuses
88
Requirements for a Firmware Update
88
Cable
89
Software for Writing to the Firmware Chip
89
Obtaining the Firmware Files
92
Saving the Device Data
92
Performing Update Operations
92
Performing a VVSP Update
92
Performing a GUI Update
93
Performing an MCU Update
94
Perform Collimator Update
112
Device and Error Messages
115
General Information about Error Messages
115
Overview of Device Messages
116
Internal Error Messages
122
Spare Parts
124
Spare Parts Generation 1
124
General Spare Parts and Tools
124
Assemblies and Device Connection
125
C-Shaped Arm
127
Cross Member
130
Column, Carriage and Wall Bracket
132
Patient Positioning
136
Wall Bracket and Head Supports
138
Spare Parts Generation 2
139
General Spare Parts and Tools
139
Overview of the Different Generations
140
Determining the Generation of the Device
140
Overview of Main Changes
141
Directory Structure
142
Overview of the Subfolders of Vistavoxplugin
142
Other manuals for Durr Dental VistaVox S
Operating Instructions
60 pages
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Durr Dental VistaVox S and is the answer not in the manual?
Ask a question
Durr Dental VistaVox S Specifications
General
Sensor Type
CMOS
Image Format
DICOM
Connection
Ethernet
Power Source
230 V / 50 Hz or 120 V / 60 Hz
Software Compatibility
DICOM-compatible software
Related product manuals
Durr Dental V 900 S
36 pages
Durr Dental VS 300 S
44 pages
Durr Dental V 1200 S
36 pages
Durr Dental VSA 300 S
44 pages
Durr Dental VistaCam iX
41 pages
Durr Dental VistaScan Mini Easy
48 pages
Durr Dental VistaScan Perio Plus
2 pages
Durr Dental VistaScan Combi View
62 pages
Durr Dental VistaScan Ultra View
62 pages
VistaScan Mini Easy 2.0
56 pages
Durr Dental VC 45
28 pages
Durr Dental Vector Paro
80 pages