Part No 94141 DC 11-Module 7.5 kW - 23
Technical data
Air pulse lter cleaning
Air consumption 4 l/s, 4 bar
Hose connection 6 mm
Electric connection without control box 24 VAC, 19A
Electric connection with control box 24 VDC, 19A
TECHNICAL DATA
Part No 14124x
Turbopump TED 30/42
Motor 7,5 kW
Frequency 50 - 70 Hz
RPM 3000 - 4200
rpm
Inlet Ø 108
Max dp 23 - 18 kPa
Nominal pres-
sure
18 - 17 kPa
Max Q 450 - 650
m
3
/h
Weight 225 kg
Sound level 1 m 62 - 67 dB(A)*
Security class IP54
Main Filter, standard
Type Pleated polyester
Part No 4292
Total lter surface 8.4 m
2
Degree of separation
EN 60335-2-69 part 1 > 99.9 %
Main Filter, optional
Type PTFE coated pleated
Part No 429203
Total lter surface 5.0 m
2
Degree of separation
EN 60335-2-69 part 1 > 99.9 %
HEPA lter (optional 2nd lter )
Part No 42136
Total lter surface 5.2 m
2
Degree of separation
EN 1822-1 HEPA H13 99.95%
Max temp lter 80
o
C
* With outlet and in-line silencer. With di user outlet the sound level is 5 dB(A) higher than the given gure.