Part No 9068 DC 11000 - 11
2009-04-06
The electrical connection should be connected to
adequate starting equipment. A certi ed electri-
cian should make the installation.
A separate, lockable disconnect must be installed
where it is readily accessible to the pump.
Installation
Connect the pipe work to the inlet and outlet.
Connect the cleaned, dried, compressed air,
4 litres/s, 4 bars to the filter cleaning. Connect
the 24 V AC control voltage from systems control
to the solenoid controlling the valve for the  lter
cleaning function.
.
Test running
1. Verify that the power is locked out.
2. Check that no persons can be injured if the
pump starts and that all outlets are closed.
3. Connect a manometer for the negative
pressure calibrated to –50 kPa to the suction
of the suction side as close to the pump as
possible.
4. Power up the pump and listen carefully for
the following sounds: A high-pitched whine
is normal from the impeller blades. As the
pump draws cooling air through the vacuum
relief valve a weak hissing should be heard.
5. Measure the pressure. Compare with the
dimension point. The pressure can be adjusted
by adjustment of the vacuum relief valve alt. For
the 9.2 kW S, the cooling air inlet.
6. Check the function and tightness of the
connected exhaust system.
7. It is normal that the pump gets hot during
operation
8. When the filter is to be cleaned, the inlet
shutter will close and a number of clear air
pulses should be heard by approx. 5 seconds
interval.
ENGLISH
Accessories
Description Part No
Fine lter, polyester 4292
Plastic sac, 90 l 4614
Plastic container, 30 l,
with attachment 40045
The warranty period is for one year for single
shift operation or equivalent time with multi shift
operation.
The warranty covers manufacturing defects. This
warranty is null and void for machines equipped
Warranty
with other than original spare parts. Warranty
repairs must be performed by Dustcontrol or
their authorized agent. Unauthorized repairs
forfeit this warranty.
Other accessories, see Dustcontrol catalogue.