Owner’s Manual – Proflo Electric Storage Water Heaters
5
H0421 0421 Rev. Q
Filling and Draining
Filling the Water Heater:
The water heater must be lled with water
before turning on the electrical supply.
1. Open all hot water taps.
2. Open the isolating valve at the cold
water inlet slowly and allow the water
heater to ll until water ows through the
system.
3. Close each hot water tap after the air is
expelled from its line.
4. Open the Pressure & Temperature Relief
Valve for approximately 10 seconds
by lifting the easing lever on the valve.
Conrm water is relieved to waste
through the relief valve drain pipe.
5. Lower the lever gently and check it
closes correctly.
Draining the Water Heater:
1. Turn off the electricity supply to the
water heater.
2. Turn off the cold water supply to the
water heater at the isolating valve.
3. Gently operate the easing lever on the
Pressure & Temperature Relief (PTR)
Valve to release the pressure in the
water heater.
4. Disconnect the cold water inlet union
and attach a drain hose to the water
heater.
5. Gently operate the easing lever on the
PTR Valve to let air into the water heater
and allow water to escape through the
hose.
Note: a combined isolating valve/non-return valve/line strainer may be used.
The expansion control valve is only required where local regulations demand, although it is
recommended in areas where the water saturation index is greater
than 0.40.