Maintenance
The BlueWave 75 was designed to operate with minimum maintenance and following basic steps below will
assure continued top performance.
Lightguide Maintenance
Clean the Lightguide ends monthly or as required. The ends of the Lightguide should be kept clean to transmit
as much energy as possible. Cured adhesive can be removed with a razor blade or isopropyl alcohol (IPA).
Avoid tight radius bends of the Lightguide since this will reduce output and may cause permanent damage to
the guide.
Fuse Replacement
The unit has two Fuses that are installed in the Power Receptacle. To remove the Fuses, unplug the unit and
remove the Fuse Holder with a small screwdriver (Figure 12). Remove the Fuses from the Fuse Holder and
install new Fuses. Replace the Fuse Holder into the Power Receptacle (Figure 14).
Fan Filter Maintenance
The external Fan Filters should be inspected and
cleaned periodically to prevent dust buildup from
affecting airflow through the unit. Spare Fan Filters
are provided with each unit and with replacement
Bulbs. The Fan Filters are washable and may be
reused. Remove the Fan Filter by removing the
Snap-On Cover from the rear of each Grill.