Manual & Automatic Close Timers
DYNACO USA, INC, 8 The Leader in Door Safety & Design
The Dynalogix II has two automatic close timers. The first timer, MC/PB timer,
will count down after a activation is installed on terminal number 2 (most
commonly used for pull cords or pushbuttons). MC/PB timer also can be
turned on or off, making it manual operation or automatic operation simply by
assigning a countdown value to the timer. The second timer, AC/Loop timer,
will count down after a activation is installed on terminal 4 (most commonly
used are motion sensors and loops). If this timer is set to zero, the door will
come down after door reaches upper limit.
1. Press and release MC/PB Timer button on the Dynalogix II controller.
The display will change to: MC Delay_Time=##. See figure 4.1-1.
2. Use the Up and Down arrow buttons to change the countdown time to the
desired duration. The Dynalogix II will automatically save any changes that
are made. See figure 4.1-2.
4.0 Setting the Manual & Automatic Close Timers
Figure 4.1-2: Raise/Lower Manual Timers
JOG
UP/RESET
JOG
DOWN
OPEN CLOSE
MC/PB AC/LOOP
PROGRAM
CLOSE
TIMERS
RUN
TIMERS
MENU
ENTER
Increase
Setting
Decrease
Setting
4.1 Setting MC/PB Timer
Figure 4.1-1: MC/PB Timer
JOG
UP/RESET
JOG
DOWN
OPEN CLOSE
MC/PB AC/LOOP
PROGRAM
CLOSE
TIMERS
RUN
TIMERS
MENU
ENTER
MC/PB
Timer
MESSAGE DISPLAY / COUNTER
MC Delay
Time=##