Rhino to RHINO2 Conversion Guide Page 13
Install the logic cable adaptor
For all RHINO2 variants, connect the RHINO2
LOGIC ADAPT LOOM (part no., GLM51987)
between the RHINO2 controller (14-way
connector) and the existing tiller head
connector (8-way). The table below shows the
corresponding mapping between the two
connectors.
GLM51987: Fit to RHINO2 tiller connector
GLM51987: Fit to existing Rhino 8-way tiller
connector
Rhino
8-way
Logic Connector
RHINO2
14-way
Logic Connector
Function
Active
Slow To
Latch
Flash
Pin 1
Pin 5
Key switch, Status LED
-
-
-
-
Pin 2
Pin 8
Throttle -
-
-
-
-
Pin 3
Pin 1
Throttle Wiper
-
-
-
-
Pin 4
Pin 2
Throttle +
-
-
-
-
Pin 5
Pin 3
Beeper
-
-
-
-
Pin 6
Pin 4
Slow/Stop, SRW
Low
50%
No
No
Pin 7
Pin 12
Reverse Drive,
Actuator Select
Low
-
-
-
Pin 8
Pin 14
Charging Inhibit
Low
-
No
No
For more information, see the RHINO2
Installation Manual, section 3.9 and the